Facility Info
246
Ducommun AeroStructures
Rec'd a letter on 7/26/05 stating that the name of this company/facility has changed from Aerochem, Inc. to Ducommun AeroStructures. 8/1/05 bw
- N/A
- 34.60020
- -117.58061
- No
- 0
- 0
- 9
- 5
- 52
- N/A
- 332812
- 3479
- 447E/3829N
- No
- 11
Zone 7 - District Office Area West, round trip 1 hour, intrazone 0.5 hours
- Yes
- 4
- 6
- S
- Active
- No
- Yes
- N/A
- Yes
- N/A
- No
- 12/31/1969
- 11/01/2016
Permit Number | Permit Description | Equipment Description | Issue Date | Expiration Date | Action | |
---|---|---|---|---|---|---|
T005201 | PROCESS TANK, B-LINE, NITRIC ACID, FOR PICKLING ... | Tank B-6, is 10 ft in diameter and 9 ft deep of ... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T005199 | PROCESS TANK, B-LINE, NITRIC ACID, FOR PICKLING ... | Tank B-3, cross-linked construction, 11.5 ft in ... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T005198 | PROCESS TANK, B-LINE, HYDROFLUORIC AND NITRIC AC... | Tank B-1, cross-linked polyethylene construction... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T005200 | PROCESS TANK, B-LINE, HYDROFLUORIC AND NITRIC AC... | Tank B-4, cross-linked polyethylene construction... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T001592 | PROCESS TANK, HYDROFLUORIC AND NITRIC ACID, FOR ... | Tank B-2, cross-linked polyethylene construction... | 08/05/1998 | 11/30/1998 |
Download Permit Print Permit |
|
T004611 | STORAGE TANKS (EMERGENCY USE) | Up to 4 Steel Tanks, which are contained in conc... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T002496 | PROCESS TANK - HYDROCHLORIC ACID FOR PICKLING ST... | Tank number G-4, which is made of cross-linked p... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T002500 | PROCESS TANK - HYDROCHLORIC ACID FOR PICKLING ST... | Tank number H-4, which is made of cross-linked p... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T000389 | PROCESS TANK, C-LINE, MIXED ACIDS (HF AND HNO3),... | Tank No. C-2, which is a PVC lined stainless ste... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T001575 | PROCESS TANK, C-LINE, MIXED ACIDS (HF AND HNO3) ... | Tank No. C-1, which is PVC lined stainless steel... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T000391 | PROCESS TANK, C-LINE, NITRIC ACID, PICKLING TITA... | Tank No. C-4, which is PVC lined stainless steel... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T000392 | PROCESS TANK - WITH NITRIC ACID FOR PICKLLING TI... | Tank No. B-4, which is PVC lined stainless steel... | 05/21/2025 | 07/29/1998 |
Download Permit Print Permit |
|
T000394 | PROCESS TANK, A-LINE, HEATED CAUSTIC FOR MILLING... | Tank No. A-1, which is of mild steel, to contain... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T000395 | PROCESS TANK, A-LINE, HEATED CAUSTIC FOR MILLING... | Tank No. A-2, which is mild steel for using 25 %... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T000564 | MASKANT DIP TANK | Tank, which is 13.3 ft by 5 ft by 6 ft deep, wit... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T001572 | PROCESS TANK - MIXED ACID (HF & HNO3) FOR MILLIN... | Tank No. B-3, which is PVC lined stainless steel... | 05/21/2025 | 07/29/1998 |
Download Permit Print Permit |
|
T001573 | PROCESS TANK - MIXED ACIDS (HF AND HNO3) FOR MIL... | Tank No. B-1, which is PVC lined stainless steel... | 05/21/2025 | 07/29/1998 |
Download Permit Print Permit |
|
T001596 | STORAGE TANK, HYDROCHLORIC ACID | Tank HCl ST, which is cross-linked polyethylene ... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T002062 | STORAGE TANK, MIXED ACIDS (HF, HCl AND HNO3) | Tank No. 404 (E-2), which is cross-linked polyet... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T002063 | STORAGE TANK, MIXED ACIDS (HF, HCl AND HNO3) | Tank No. E-1, which is cross-linked polyethylene... | 12/03/2024 | 11/30/2025 |
Download Permit Print Permit |
|
T002065 | STORAGE TANK - MIXED ACIDS (HF, HCl AND HNO3) | Tank No. S-5, which is cross-linked polyethylene... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T002069 | STORAGE TANK - MIXED ACIDS (HF, HCl AND HNO3) | Tank S-1, which is cross-linked polyethylene for... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T003696 | CLEANING TANK - NITRIC ACID | Tank K-3 is approximately 6 ft by 5 ft by 4 ft d... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T003697 | PICKLING TANK - NITRIC ACID | Tank C-8 which is 3 ft by 2.8 ft by 3 ft deep an... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |
|
T003698 | CLEANING TANK - SULFURIC ACID/PHOSPHORIC ACID | Tank C-7 which is 3 ft by 2.8 ft by 3 ft deep wi... | 11/23/2022 | 11/30/2023 |
Download Permit Print Permit |